What Size Dehumidifier Do I Need? Pints per Day by Area

What size dehumidifier do you need for a basement or crawlspace? Enter the area and how damp it is for the pints per day, rated on the 2019 label.

Dehumidifier Size Calculator

Pints per day on the 2019 label
sq ft
20 pints/day
Unit size, 2019 label
17 pints/day
Moisture to remove, 2019 test
  • Sized on the 2019 label. By the relabeling makers did after that test change, an older unit of similar capacity would have been labeled about 24 pints.

An estimate from the space size and how damp it is. Real moisture load depends on leaks, drainage, the climate and how the space is used. A licensed contractor confirms the size.

The results on this page come from public data and general rules of thumb, applied to what you entered. They can be wrong or out of date, and they may not fit your home. They are not professional advice, an inspection or an offer of service. Before you act on anything here, check it with a licensed pro or the agency named on the page. Any decision you make is your own, and we are not responsible for losses from relying on these results.

Data: pints by area and dampness follow the shape of ENERGY STAR’s dehumidifier sizing chart, read here as the minimum on the 2019 label; DOE dehumidifier test procedure (10 CFR 430, Appendix X1, effective 2019); EPA indoor humidity guidance; July dewpoint when a town is named. The 10% step for humid summers (a July dewpoint of 65°F or more) and the 50 to 70 pint scale for older labels are this tool’s own rules · Updated November 2026

How to size a dehumidifier for a basement

Dehumidifier pints per day by area and dampness

A dehumidifier is rated by the pints of water it pulls from the air in a day. The tool starts at 10 to 16 pints for 500 sq ft, depending on how damp the space is, and adds 4 to 7 pints for each extra 500 sq ft. That follows the shape of the sizing chart ENERGY STAR has long published.

Why dehumidifier pint ratings changed in 2019

In 2019 the Department of Energy changed the test. Units used to be rated at 80°F and are now rated at 65°F, closer to a real basement. The same machine pulls less water in cooler air, so the new label reads lower. Compare sizes on the same label year.

Why a basement stays damp with a dehumidifier running

A dehumidifier dries the air in the space. Water coming through the walls or floor needs its source found, and a waterproofing contractor or plumber can trace it. For a crawlspace, an HVAC contractor can size a unit built for that space.

Dehumidifier sizing questions

What size dehumidifier do I need for a basement?

A very damp 1,000 sq ft basement needs about 17 pints a day on the 2019 label, so a 20 or 22 pint unit. An extremely wet one of the same size needs about 23, so a 35 pint unit. Past 50 pints the tool suggests a whole-house unit or two portables.

Is a 50 pint dehumidifier the same as a 70 pint?

Makers relabeled their 70 pint units as about 50 pints under the 2019 DOE test, with no change to the machine. The tool uses that 50 to 70 ratio as a rough scale for older labels. It is not an official conversion.

What humidity should a basement be?

EPA advises keeping indoor humidity below 60%, and ideally between 30% and 50%, to limit mold growth. A hygrometer reads it.

Do I need a whole-house dehumidifier?

An HVAC contractor can look at one when a single space needs more than a 50 pint portable unit, or when the whole home stays humid in summer. A whole-house unit ties into the ductwork and dries the air the system moves.