Whole-House Ventilation Calculator: ASHRAE 62.2 Fresh Air CFM

How much whole-house ventilation does your house need? Get the continuous fresh air rate in CFM from floor area and bedrooms, by the ASHRAE 62.2-2019 formula.

Whole-House Ventilation Calculator

Fresh air rate by the ASHRAE 62.2-2019 formula
sq ft
90 CFM
Continuous fresh air
90 CFM
Fan rate

0.03 x 2,000 sq ft + 7.5 x (3 bedrooms + 1) = 90 CFM.

  • That is about 0.34 air changes an hour for a home with 8 ft ceilings.
  • An HVAC contractor can tell you whether an existing bath fan can carry this rate on a schedule, or whether a separate fan or a balanced ERV or HRV system fits the house better.
  • The standard allows a lower rate for an older, leakier home once a blower door test measures the leakage.

An estimate from the ASHRAE 62.2-2019 formula before any credit for air leakage. The right system depends on the house, the climate and local code. A licensed contractor confirms the size.

The results on this page come from public data and general rules of thumb, applied to what you entered. They can be wrong or out of date, and they may not fit your home. They are not professional advice, an inspection or an offer of service. Before you act on anything here, check it with a licensed pro or the agency named on the page. Any decision you make is your own, and we are not responsible for losses from relying on these results.

Data: ASHRAE Standard 62.2-2019 total ventilation rate formula; DOE Building America whole-house ventilation guidance. The part-hour fan rate is this tool’s simpler version of the standard’s intermittent method, and the air changes figure assumes 8 ft ceilings · Updated November 2026

How to calculate whole-house ventilation

Whole-house ventilation rate by floor area and bedrooms

Whole-house ventilation is the steady fresh air a home needs. ASHRAE Standard 62.2-2019 bases it on floor area and on people, counting one more person than bedrooms. A 2,000 sq ft, 3 bedroom home works out to 90 CFM, running all the time.

Why airtight houses need mechanical ventilation

Newer and air-sealed homes let far less outdoor air in through cracks. That holds heat in, but moisture, cooking smells and indoor pollutants build up too. A ventilation fan brings in a steady, planned amount of fresh air.

Fan rate when it runs part of each hour

A fan that runs 30 minutes each hour has to move about twice the air while it is on, and one that runs 20 minutes about three times. This is a simpler version of the standard’s method for fans that cycle.

Whole-house ventilation questions

How much ventilation does a house need?

For a 1,500 sq ft, 2 bedroom home, about 68 CFM of fresh air running all the time, by ASHRAE 62.2-2019. A 2,500 sq ft, 4 bedroom home needs about 113.

Does a bathroom fan count as whole-house ventilation?

It can, if it is sized for the whole-house rate and set to run on a schedule or all the time. A fan that only runs during showers does not count.

What is the difference between an ERV and an HRV?

Both bring in fresh air and send out stale air while passing heat between the two streams. An ERV also passes moisture, which suits humid summers and dry winters. An HVAC contractor matches one to the climate.

What is the ASHRAE 62.2 ventilation formula?

In the 2019 edition, 0.03 CFM per square foot of floor area plus 7.5 CFM for each bedroom plus one. Earlier editions used 0.01 CFM per square foot with a built-in allowance for leakage. The 2013 and later editions raised it to 0.03 and moved leakage into a separate credit based on a blower door test.

Related home tools