Heat Pump and Furnace Size Calculator by Square Feet
How many BTU does it take to heat your house? Estimate the furnace output and heat pump tonnage a home your size needs in your winter climate.
The results on this page come from public data and general rules of thumb, applied to what you entered. They can be wrong or out of date, and they may not fit your home. They are not professional advice, an inspection or an offer of service. Before you act on anything here, check it with a licensed pro or the agency named on the page. Any decision you make is your own, and we are not responsible for losses from relying on these results.
Data: DOE and ASHRAE heat loss method (heat loss per degree times the indoor to outdoor temperature gap); January average lows from Daymet (NASA/ORNL) when a town is named; the insulation and ceiling factors and the 15°F design offset are this tool’s own rule of thumb · Updated September 2026
How to size a furnace or heat pump for your house
What sets the heating load of a house
A home loses heat through every outside surface and through its air leaks. The bigger the house and the colder it gets outside, the more heat it takes to hold 70°F indoors. We start from your January average low, size for a colder design night, then adjust for insulation and ceiling height.
How insulation changes furnace size
A drafty older home can need about twice the heat of a sealed, well insulated one of the same size. In a cold-winter climate, a 2,000 sq ft house comes out near 39,000 BTU per hour with good insulation and near 81,000 with poor. Air sealing before replacement can mean a smaller system.
Reading the size on a furnace or heat pump label
A furnace is picked by the heat it puts out. One that turns 95% of its fuel into heat (a 95% AFUE rating) with a 100,000 BTU input delivers 95,000 BTU. A heat pump is rated at 47°F outdoors and puts out less heat as the temperature drops, so the size on its label is more than it gives on your coldest nights.
Why a Manual J load calculation sets the final size
A Manual J counts each window, wall and duct run, the direction the house faces and how leaky it is. A rule of thumb like this one gets close for a typical house. A good installer still runs the calculation before naming a size.
Furnace and heat pump sizing questions
How many BTU do I need to heat 2,000 square feet?
Roughly 40,000 to 45,000 BTU per hour in a mild-winter climate and 55,000 to 70,000 in a cold one for an average-insulation home. Climate accounts for that spread, and the insulation class then moves the number up or down by about a third. The old rule of 50 BTU per square foot runs well above what a load calculation returns and leads to an oversized furnace.
What size heat pump do I need for my house?
Divide the heating load by 12,000 to get tons, then round to the nearest half ton. In cold climates the heating load is bigger than the cooling load, so the installer checks the unit against both. A variable-speed model is one way to keep it from being oversized in summer.
Is it better to oversize a furnace to be safe?
No. An oversized furnace heats the house in short bursts, which wears parts, leaves rooms uneven and wastes fuel. Installers size close to the calculated load with a modest margin.
Does ceiling height change the heating size?
Yes. Nine and ten foot ceilings add air volume and wall area, which adds 10% to 20% to the load. Vaulted rooms with big windows can add more, and a load calculation counts them.
What is a winter design temperature?
The outdoor temperature your area stays above for about 99% of winter hours. It sits well below the January average low, and this tool takes 15°F off that average to estimate it. Colder hours still happen, about 1 in every 100.