Well Pressure Tank Size Calculator With Drawdown and Pre-Charge

What size pressure tank does a well pump need? Enter the pump flow and pressure switch setting to get the drawdown per cycle, total tank volume and pre-charge.

Well Pressure Tank Calculator

Drawdown and tank size from pump flow and switch setting
GPM
44 gal
Total tank volume (next common size)
10 gal
Drawdown per pump cycle

pre-charge 38 psiWorks out to about 39 gallons of total volume.

  • On a 40/60 switch, about 26% of the tank is usable water. The rest is the air cushion that pushes it out.
  • A plumber or well contractor checks the pre-charge when the tank is serviced.
  • A tank smaller than this lets the pump shut off before it has run its minimum time. That is called short cycling.

An estimate from Boyle's law and a minimum run time. A licensed well or pump contractor confirms the tank size against your pump, switch and water use.

The results on this page come from public data and general rules of thumb, applied to what you entered. They can be wrong or out of date, and they may not fit your home. They are not professional advice, an inspection or an offer of service. Before you act on anything here, check it with a licensed pro or the agency named on the page. Any decision you make is your own, and we are not responsible for losses from relying on these results.

Data: Boyle's law for the air charge · pre-charge 2 psi below cut-in and minimum run times of 1 to 2 minutes from pump and tank maker guidance · the list of common tank sizes is this tool's own · Updated November 2026

How to size a well pressure tank

Minimum pump run time and drawdown

Each time a well pump starts, the motor heats up. Pump makers ask for a minimum run of about one minute, or two for larger pumps, so the tank has to hold enough water to keep the pump running that long. Pump flow times run time is the drawdown the tank must deliver.

Usable water in a tank, from Boyle's law

A pressure tank is mostly air. As water comes in, the air squeezes. Between cut-in and cut-out, only part of the tank fills and empties, and that share shrinks as the switch setting goes up, from about a third on 20/40 to under a quarter on 50/70. The tank's total volume is the drawdown divided by that share.

Pre-charge and a waterlogged tank

The air charge in an empty tank is set 2 psi below the cut-in pressure. A tank that loses its charge, or has a failed bladder, fills with water and delivers only a fraction of its drawdown, and the pump starts to short cycle.

Well pressure tank questions

What size pressure tank do I need for a 10 GPM pump?

At a one-minute run time and a 40/60 switch, about 10 gallons of drawdown, which takes a tank of about 39 gallons total volume. The next common size up is 44 gallons.

What should the pre-charge be on a well tank?

28 psi for a 30/50 switch, 38 psi for 40/60 and 48 psi for 50/70. The pre-charge is the air pressure in the tank when it holds no water.

What is drawdown on a pressure tank?

The water a tank delivers between the pump shutting off and turning back on. It is a fraction of the tank's total volume, so a 44 gallon tank on a 40/60 switch gives about 11 gallons per cycle.

What happens if a pressure tank is too small?

The pump starts more often than it should, and each start heats the motor and wears the pressure switch contacts. The pressure at the tap also swings more. A well contractor can tell whether the tank is too small for the pump.