Sump Pump Sizing: Total Dynamic Head to Match on a Pump Curve

How much head does a sump pump need? Add the vertical lift, horizontal run, pipe size and fittings for the total dynamic head to look for on a pump curve.

Sump Pump Head Calculator

Total dynamic head to match against a pump curve
feet
feet
11.2 ft
Total dynamic head
30 GPM
Flow, about 4.7 ft/s in 1 1/2 inch pipe
  • On the pump's curve, look for at least 30 GPM at 11.2 feet of head. A pump that only meets it at the very end of its curve has nothing to spare.
  • Friction adds about 3.2 feet on top of the 8 foot lift: 28 feet of pipe plus 25.5 feet counted for the fittings.
  • A plumber also checks where the line ends. Water let out next to the foundation can soak back down to the pit, and a line outdoors in a cold climate can freeze shut.
Check how much water risk the space has

An estimate of total dynamic head from standard friction figures. A licensed plumber confirms the pump and discharge line against the real pit, pipe and fittings.

The results on this page come from public data and general rules of thumb, applied to what you entered. They can be wrong or out of date, and they may not fit your home. They are not professional advice, an inspection or an offer of service. Before you act on anything here, check it with a licensed pro or the agency named on the page. Any decision you make is your own, and we are not responsible for losses from relying on these results.

Data: Hazen-Williams friction for schedule 40 PVC (C = 140) · fitting allowances of 30 pipe diameters per elbow and 100 per check valve are this tool's own working figures, from standard equivalent-length practice · Updated November 2026

Sump pump sizing by total dynamic head

Vertical lift from the pit to the discharge

Head is measured in feet of water. The vertical lift runs from the floor of the pit to the highest point of the discharge line, which is where the line turns to leave the house.

Friction loss in the pipe and fittings

Water rubbing along the pipe, and turning through elbows and a check valve, takes extra head. This tool counts each 90 degree elbow as about 30 pipe diameters of straight pipe, and the check valve as more than three elbows.

Reading a sump pump curve

Every pump maker publishes a curve of flow against head. Find the head from this tool on the curve and read across to the flow the pump makes there. Flow drops as head rises, so the same pump moves less water up a taller or longer line.

Sump pump sizing and head questions

What is total dynamic head on a sump pump?

The vertical lift plus the head lost to friction in the pipe and fittings, in feet. It is the head to read on a pump curve, because the lift alone leaves the friction out.

Does pipe size change sump pump performance?

Yes. At 30 GPM, 100 feet of 1 1/4 inch pipe loses about 13 feet of head to friction, 1 1/2 inch about 6 and 2 inch under 2. The pump moves less water through the smaller line.

How many gallons per minute should a sump pump move?

Enough to keep up with the water coming into the pit in a heavy storm. A plumber can work out that inflow by timing how fast the pit fills. This tool checks flows from 20 to 50 GPM.

Does a check valve affect head?

It adds friction. This tool counts a check valve as about 100 pipe diameters of straight pipe, which is about 13 feet of 1 1/2 inch pipe or 17 feet of 2 inch. A sump line still gets one because it keeps the water in the line from falling back into the pit each time the pump stops.