Electrical Panel Load Calculator for an EV Charger or Heat Pump
Can your electrical panel handle an EV charger, a heat pump or a hot tub? Compare the estimated load of your home with your panel size in amps before you call.
The results on this page come from public data and general rules of thumb, applied to what you entered. They can be wrong or out of date, and they may not fit your home. They are not professional advice, an inspection or an offer of service. Before you act on anything here, check it with a licensed pro or the agency named on the page. Any decision you make is your own, and we are not responsible for losses from relying on these results.
Data: National Electrical Code (NFPA 70, 2023 edition) section 220.83, the optional method for existing dwellings · typical appliance nameplate ratings chosen for this tool · Updated September 2026
How to tell if your electrical panel has enough capacity
The base load from lights and outlets
Lights and everyday outlets draw power whether or not anything big is plugged in. We work that base out at 3 watts per square foot of living area and add a standard amount for the kitchen counter circuits and the laundry circuit.
Large electric appliances that add to the load
Each large appliance you tick adds a typical nameplate rating. An electric range counts the most, at about 50 amps, and a hot tub or an electric dryer adds about 23 to 29. Tick only the ones that run on electricity in your home.
Why the total is less than everything added up
A range, a dryer and a water heater do not all draw full power at the same moment. So the standard method counts the first 8,000 watts of those loads in full and 40 percent of the rest. Heating or cooling, whichever is larger, is counted in full. We also count a Level 2 EV charger in full because it draws steadily for hours, which is more cautious than the standard method.
How the estimate compares with your main breaker
We turn the total into amps at 240 volts and compare it with the main breaker rating. Up to 80 percent of the rating is the lowest of three levels, up to 100 percent is near the rating, and anything higher is over it. At either upper level, have an electrician run a full load calculation before anything new is added.
Electrical panel load and capacity questions
How do I know what size electrical panel I have?
Look at the main breaker at the top of the panel. Its rating is printed on the handle, for example 100, 150, or 200. You can read it without removing the cover.
Can a 100-amp panel handle a Level 2 EV charger?
It depends on what else in the house is electric. A home with gas heat, gas water heating, and a gas range carries far less load than an all-electric home. Run the numbers above with your actual loads, then have an electrician do the real calculation.
Do I need a 200-amp panel for a heat pump?
Not always. On this checker, a heat pump that replaces a central air conditioner of the same size adds nothing to the cooling load, since both carry the same rating. The backup electric heat strips are what can push a panel over, so their size counts for more than the heat pump itself.
Is this the same load calculation an electrician does?
It follows the same steps, with typical ratings standing in for your real appliances. An electrician uses the nameplate ratings on your own equipment, checks the service size, and can measure what the home actually draws.
What if my panel is full but the amps work out?
Then the limit is breaker spaces. A panel with no open spaces may need a subpanel even when the load calculation shows room, and some panels do not allow tandem breakers.