Tankless Water Heater Size Calculator by GPM and Rise
What size tankless water heater does your home need? Pick the showers and extra loads at once for the gallons per minute, temperature rise and unit size.
The results on this page come from public data and general rules of thumb, applied to what you entered. They can be wrong or out of date, and they may not fit your home. They are not professional advice, an inspection or an offer of service. Before you act on anything here, check it with a licensed pro or the agency named on the page. Any decision you make is your own, and we are not responsible for losses from relying on these results.
Data: DOE water heater guidance (120°F setpoint) · federal maximum showerhead flow (2.5 GPM) · this tool’s own figures for faucet (1.8 GPM) and dishwasher or washer (2 GPM) flow and for groundwater by winter (42, 52 or 65°F) · town January low when a town is named · Updated September 2026
How to size a tankless water heater
Adding up the fixtures that run at once
A tank stores hot water. A tankless unit heats water as it flows through, so its size comes from gallons per minute. Add up the fixtures that run together. This tool counts a showerhead at 2.5 GPM, a faucet at 1.8 and a dishwasher or washer at 2. A shower mixes hot and cold, so only about three quarters of its flow is hot water from the heater, and two showers at once come to about 4 GPM of hot water.
Groundwater temperature and the rise to 120°F
The unit has to lift incoming water to the setpoint, and 120°F is the setting the Department of Energy recommends. This tool assumes groundwater near 42°F where winters are cold, a rise of 78°F, near 52°F where they are mild, and near 65°F where it is warm all year, a rise of 55°F.
Turning flow and rise into BTUs per hour
The heat a unit must add each hour is the flow in GPM, times the rise, times 500 (from the weight of a gallon of water over an hour). Two showers at a 68°F rise come to 3.9 × 68 × 500, about 133,000 BTU per hour. The same unit gives fewer gallons per minute as the rise grows, which is why maker charts list flow by rise.
Which unit class fits the load
The result sorts the heat load into four classes. Up to about 90,000 BTU per hour is a small unit that handles one shower at a time. Up to 150,000 is a standard whole-house unit, and up to 190,000 a large one. Past that, two units are linked to share the load.
Tankless water heater sizing questions
What size tankless water heater do I need for a family of four?
Plan for two showers at once. Where winters are mild or warm, that fits a standard whole-house unit. In a cold-winter state it lands on a large unit, because the incoming water is colder. Pick your winters above to see which applies.
Can a tankless water heater run two showers at once?
Yes, if it is sized for the job. With gas, two showers fit one standard unit in a mild or warm climate and a large unit where groundwater is cold. With electric, even the largest common unit covers two showers only where groundwater is warm. Adding a faucet or an appliance at the same time can push a gas setup to two linked units.
What is temperature rise on a tankless water heater?
The difference between the incoming water temperature and the setpoint. With 120°F out and 45°F in, the rise is 75°F. Every tankless flow rating is given at a rise, so a unit rated 9 GPM at a 35°F rise gives far less in a cold climate.
Is an electric tankless water heater enough for a whole house?
It depends on the groundwater. The largest common electric units, about 36 kW, give about 3.1 GPM at a 78°F rise, enough for one shower with a little to spare. Where groundwater is warm, the same unit gives about 4.5 GPM. An electrician confirms whether your service can carry one.
Does a tankless water heater need a bigger gas line?
It can. A large gas tankless unit burns gas several times faster than a tank heater, and the existing gas line and venting may not be sized for it. A plumber checks both early in a tankless conversion.