Drain Pipe Size Calculator for Showers, Tubs, Sinks and Toilets

What size drain pipe does a shower, tub, sink or toilet need? Add the fixtures on the line for drainage fixture units and a drain and vent size estimate.

Drain Pipe Size Calculator

Fixture units to a drain and vent size
Toilet1
Bathroom sink1
Bathtub or tub shower1
Kitchen sink0
3 inch
Drain size for this line
1 1/2 inch
Vent size estimate

7 drainage fixture unitsAbout 11.3 GPM at peak, from 3 fixtures.

  • The flow sets the size here. A 3 inch drain at this slope carries about 31 GPM running half full.
  • The building drain that carries every line out of the house is sized for the whole house load, and some local rules set 4 inch as the minimum for the sewer pipe outside.
  • The vent size is an estimate from the drain size alone. A plumber also counts the vent's length and how many fixtures share it.

An estimate from fixture units and pipe flow. Local plumbing codes publish their own tables, and a licensed plumber confirms the drain and vent sizes.

The results on this page come from public data and general rules of thumb, applied to what you entered. They can be wrong or out of date, and they may not fit your home. They are not professional advice, an inspection or an offer of service. Before you act on anything here, check it with a licensed pro or the agency named on the page. Any decision you make is your own, and we are not responsible for losses from relying on these results.

Data: Hunter's fixture-unit method and demand curve (NBS BMS 65 and BMS 66, 1940) · pipe flow from Manning's equation at half full · the fixture-unit values (a toilet at 4), the single-fixture minimums and the half-size vent rule are this tool's own residential estimates, not a code table · Updated November 2026

How to size a drain pipe from fixture units

Drainage fixture units for each fixture

Each fixture gets a drainage fixture unit value for how much water it sends down the drain and how often. This tool counts a bathroom sink as 1, a tub, shower or kitchen sink as 2, a washer as 3 and a toilet as 4. The method goes back to Roy Hunter at the National Bureau of Standards in 1940.

Turning fixture units into peak flow

Ten fixtures rarely drain at the same moment, so Hunter used probability to turn a fixture-unit total into a peak flow in gallons per minute. The drain has to carry that peak. His curve was built for older, thirstier fixtures, so it can run high for a house with low-flow toilets and faucets.

Pipe slope and drain capacity

A horizontal drain is sized to carry its peak flow while running about half full, so air can move over the water and the traps keep their seal. The flatter the line, the less it carries, which is why slope is the second input here. Lines under 3 inch are run at 1/4 inch per foot whichever slope you pick.

Minimum sizes set by single fixtures

Some fixtures set a floor however small the total load is. A toilet sets the line at 3 inch or more, and a shower stall or washer at 2 inch. When one of them decides the size, the result says so.

Drain and vent sizes for showers, tubs and toilets

What size drain pipe does a toilet need?

At least 3 inch. A toilet sends a large slug of water and solids at once, and plumbing codes set 3 inch as the smallest drain that carries one. In this tool, three toilets, four bathroom sinks, two tubs, a shower stall, a kitchen sink, a dishwasher and a washer on a 1/8 inch slope size the main drain at 4 inch.

What size drain does a shower or bathtub need?

This tool uses 2 inch for a shower stall and 1 1/2 inch for a tub or tub shower, the smallest trap sizes in current model plumbing codes. A shower with several heads or body sprays sends more water, and a plumber sizes its drain from that flow.

What is a drainage fixture unit?

A unit of drain load. One fixture unit was set at roughly the flow of a bathroom sink, and other fixtures are rated against it. Adding them up lets a plumber size a drain without guessing at how many fixtures run at once.

How big should a vent pipe be?

About half the diameter of the drain it serves and never smaller than 1 1/4 inch, as a rule of thumb. A vent through the roof in a cold climate can be made larger so frost does not close it. Local code sets the final size.